We are the supplier and exporter of low & medium voltage electric equipements: Electric Connectors, Industrial Plugs, XAC Pendent Pushbutton Switches, APP SB Power Connectors ,Contacts,Split Core Transformer, Clamp Transformer, Distribution box, LED Lampes. And crane parts: Electirc Hoist, Terminal Blocks, COB,XAC Pendant Control Stations, Crane Overload Detector, Cut off limit..

Albright Emergency Disconnect switch

Albright Emergency Disconnects

 Main TerminalRatingTypeConfigurationView

STUD125 AED125SP ST ON/OFF

STUD125 A   ED125L    SP ST ON/OFF

STUD150 A   ED150      SP ST ON/OFF

STUD250 A   ED250SP   ST ON/OFF

STUD250 A    ED250L    SP ST ON/OFF

STUD250 A    ED252      DP  ST ON/OFF

STUD250 A   ED252L    DP ST ON/OFF

STUD400 A   ED402    DP ST ON/OFF

STUD400 A    ED402L    DP ST ON/OFF

STUD125 A    SD150     SP ST NO with manual disconnect

STUD125 A    SD150A    SP ST NO with manual disconnect

STUD125 A   SD150AL    SP ST NO with manual disconnect

STUD200 A    SD200     SP ST NO with manual disconnect

STUD250 A   SD250    SP ST NO with manual disconnect

STUD250 A   SD250A    SP ST NO with manual disconnect

STUD250 A    SD250AL     SP ST NO with manual disconnect

STUD300 A    SD300      SP ST NO with manual disconnect

STUD80 A      ED80       SP ST ON/OFF


ED125 Emergency disconnect switch  
Main Contact Configuration
SP ST ON/OFF
STUD, M8
Thermal Current Rating 100%
 125A
Typical fault currents which can be ruptured
(5ms time constant)
Without Blowouts800A at 48V D.C.
With Blowouts800A at 80V D.C.
Maximum Recommended Contact Voltages
(Inductive Load)
Without Blowouts48V D.C.
With Blowouts96V D.C.
Typical Voltage Drop Across Contacts per 100A
Normally Open40mV
Mechanical Life
Manually Operated>10 x 103
Auxiliary contact thermal current rating
 15A
Auxiliary Contact Switching Capacities (Resistive Load)
15A at 24V D.C.
10A at 48V D.C.
5A at 96V D.C.
Typical Weight
300gms

ED125L Emergency disconnect 
Main Contact Configuration
SP ST ON/OFF
STUD, M8
Thermal Current Rating 100%
 125A
Typical fault currents which can be ruptured
(5ms time constant)
Without Blowouts800A at 48V D.C.
With Blowouts800A at 80V D.C.
Maximum Recommended Contact Voltages
(Inductive Load)
Without Blowouts48V D.C.
With Blowouts96V D.C.
Typical Voltage Drop Across Contacts per 100A
Normally Open40mV
Mechanical Life
Manually Operated>10 x 103
Auxiliary contact thermal current rating
 15A
Auxiliary Contact Switching Capacities (Resistive Load)
15A at 24V D.C.
10A at 48V D.C.
5A at 96V D.C.
Typical Weight
300gms

ED150  disconnect switch  
Main Contact Configuration
SP ST ON/OFF
STUD, M8
Thermal Current Rating 100%
 150A
Typical Voltage Drop Across Contacts per 100A
Normally Open40mV
Mechanical Life
Manually Operated>10 x 103
Auxiliary contact thermal current rating
 15A
Auxiliary Contact Switching Capacities (Resistive Load)
15A at 24V D.C.
10A at 48V D.C.
5A at 96V D.C.
Typical Weight
300gms

ED250 battery  disconnect switch 
Main Contact Configuration
SP ST ON/OFF
STUD, M8
Thermal Current Rating 100%
 250A
Typical fault currents which can be ruptured
(5ms time constant)
Without Blowouts1000A at 48V D.C.
With Blowouts1000A at 96V D.C.
Maximum Recommended Contact Voltages
(Inductive Load)
Without Blowouts48V D.C.
With Blowouts96V D.C.
Typical Voltage Drop Across Contacts per 100A
Normally Open30mV
Mechanical Life
Manually Operated>10 x 103
Auxiliary contact thermal current rating
 15A
Auxiliary Contact Switching Capacities (Resistive Load)
15A at 24V D.C.
10A at 48V D.C.
5A at 96V D.C.
Typical Weight
450gms

ED250L battery  disconnect
Main Contact Configuration
SP ST ON/OFF
STUD, M8
Thermal Current Rating 100%
 250A
Typical fault currents which can be ruptured
(5ms time constant)
Without Blowouts1000A at 48V D.C.
With Blowouts1000A at 96V D.C.
Maximum Recommended Contact Voltages
(Inductive Load)
Without Blowouts48V D.C.
With Blowouts96V D.C.
Typical Voltage Drop Across Contacts per 100A
Normally Open30mV
Mechanical Life
Manually Operated>10 x 103
Auxiliary contact thermal current rating
 15A
Auxiliary Contact Switching Capacities (Resistive Load)
15A at 24V D.C.
10A at 48V D.C.
5A at 96V D.C.
Typical Weight
450gms

ED252 battery switch
Main Contact Configuration
DP ST ON/OFF
STUD, M8
Thermal Current Rating 100%
 250A
Typical fault currents which can be ruptured
(5ms time constant)
Without Blowouts1500A at 48V D.C.
With Blowouts1500A at 96V D.C.
Maximum Recommended Contact Voltages
(Inductive Load)
Without Blowouts96V D.C.
With Blowouts150V D.C.
Typical Voltage Drop Across Contacts per 100A
Normally Open40mV
Mechanical Life
Manually Operated>10 x 103