SW60 albright 12V 24V DC single acting minature solenoid contactor
ZJW50A DC contactors for battery rectification power
SW60 albright 12VDC contactor
albright SW60 24V DC single acting minature solenoid contactor
albright SW60 DC single acting minature solenoid
other series number of SW60 contactL
ZJW50A series DC contactors are suitable for the battery or the rectification power, using for handling drawing, the pump motor and other electronic vehicles. At the same time it has been widely used in communications power, intermittent power supply and other electronic control system
Brief Technical Data:
Number |
Type and parameter |
Coil& rated volt of contact circuit(v) |
12 |
24 |
3 0 |
36 |
40 |
48 |
60 |
72 |
8 80 |
1 |
Coil power dissipation <15(w), Max.coil current(A) |
0.98 |
0.58 |
0.45 |
0.35 |
0.32 |
0.28 |
0.25 |
0.2 |
0.18 |
2 |
main rated load current of contact circuit(A) |
Resistive load:て=1ms 50A
Max.Rated working current of contact circuit for4le,5 seconds |
3 |
voltage |
50Hz 1000V AC 1min |
4 |
Operating time |
Pickup(contact makes):≯30ms , Release(contact breaks):≯30ms |
5 |
Action characteristic |
Pickup(contact makes):≯66%Us
Release(contact breaks):≯30%Us,≮5%Us |
6 |
Mechanical life |
1 million times |
7 |
Electric life |
Resistive load:50000times,inductive load(DC-5): 60%le for Resistive load,10000times |
Notice:
1、Specifications subject to change as the custom request
2、Coil voltage in above 48V with permanent magnet blowouts |
Environmental condition:
1. Ambient temperature:-25~+40℃
2. Altitude range:0~2000m
3. Max.relative humidity90% at 25℃
4. Vibration:10~50Hz,10m/s2
5. Shock:30m/s2
6. Installation method:anywhere
7. Voltage fluctuating:0.7~1.1Ue
8. Duty:8h continuous
Configurational mounting diagram:
Circuit diagram:
Nomination(nomogram)
SW60 Albright DC solenoid contactor