ZJ 400A DC contactor
ZJ400A contactor is applicable for electric control system of electromobile, motor forklift truck, electric vehicle, electric winch, grab, vehicle air conditioner, communication power supply, UPS (uninterruptible power system) and so on
Brief Technical Data:
Number |
Type and parameters |
Coil and rated volt of contact circuit(v) |
12 |
24 |
30 |
36 |
40 |
48 |
72 |
80 |
220 |
|
1 |
coil hold current(A) |
0.65 |
0.35 |
0.3 |
0.25 |
0.22 |
0.2 |
0.12 |
0.1 |
|
|
coil start current(A) |
≯5 |
≯5 |
≯5 |
≯5 |
≯5 |
≯5 |
≯5 |
≯5 |
|
|
2 |
ZJ400DE Coil hold current(A)(400D,48V= 0.35A)DE-For intermittently |
|
|
|
|
|
0.35 |
|
0.75 |
|
3 |
main rated load current of contact circuit(A) |
Resistive load:て=1ms,400A
Max.Rated working current of contact circuit for 4le, 5 seconds |
4 |
voltage |
50Hz 1000V AC 1min |
5 |
Operating time |
Pickup(contact makes):≯30ms, Release(contact breaks):≯30ms |
6 |
Action characteristic |
Pickup(contact makes):≯66%Us,
Release(contact breaks):≯30%Us,≮5% Us |
7 |
Mechanical life |
300 thousand times |
8 |
Electric life |
Resistive load(て=1ms):5million times,< inductive load(DC-5): 60%le for Resistive load ,2million times |
Notice:
1、Specifications subject to change as the custom request
2、ZJ400D is unicoil winding